»Test Chambers for Telcordia (Bellcore) Standard Reliability Testing

Telcordia* Generic Requirements for establishing reliability in telecommunications equipment require the use of environmental testing. Envirotronics is a leading manufacturer of the temperature and humidity test equipment needed to perform the required tests.

We would be pleased to answer any of your questions about our chambers and testing to the Telcordia Generic Requirements. If you need a copy of the specifications for Telcordia Standard Reliability Testing, they can be purchased from Telcordia.

In an effort to help simplify the process of selecting the proper environmental test chamber for your test requirements, we have constructed a simple reference chart. Select your standard from the following list and the reference chart will indicate the Envirotronics Test Chamber Series that we recommend. You will also be provided with a link to the web page that describes that particular chamber.

In the event that your browsing through our chart does not answer your questions. Contact us at 616-554-5020 or email sales@envirotronics.com.

*formerly known as Bellcore

Standards

GR-49-CORE for outdoor network interface devices

GR-63-CORE for network switching systems (NEBS)

GR-326-CORE for fiber optics

GR-468-CORE for optoelectronic devices

GR-487-CORE for enclosures

GR-1209-CORE for fiber optics

GR-1221-CORE for fiber optics

»Telcordia (Bellcore) GR-49-CORE for outdoor network interface devices

Paragraph
Test Title
Description
Envirotronics Test Chamber
5.1 R5-1 [53] High Temperature Storage/Mold Stress 70°C
5.1 CR5-1 [55] High Temperature Storage/Mold Stress 80°C
5.2 R5-4 [56] Temperature Cycling -40 to 60°C 30 minute transition
  • 5.2 CR5-5 [57] Temperature Cycling -40 to 60°C 30 minute transition
  • 5.3 R5-6 [58] Temperature Cycling with Humidity -40 to 60°C w/R.H.
  • 5.3 CR5-7 [59] Temperature Cycling with Humidity -40 to 60°C w/R.H.
  • Return to Standards List
    Return to new Environmental Test Equipment page

    »Telcordia (Bellcore) GR-63-CORE for network switching systems (NEBS)

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    5.1.1.1 Low Temperature Exposure and Thermal Shock Ramp down to -40°C at 1/2°C per minute. Hold the equipment at -40°C for 72 hours, then remove to ambient room temperature.
    5.1.1.2 High Temperature Exposure and Thermal Shock Ramp up to 70°C at 1/2°C per minute. Hold the equipment at 70°C for 72 hours, then remove to ambient room temperature
    5.1.1.3 High Relative Humidity Exposure Maintain 40°C and 90-95% R.H. for 96 hours, with controlled heat-up and cool-down
    5.1.2 Operating Temperature and Relative Humidity 14 step test profile, cycling from -5 to 50°C with humidity requirements. Equipment is operating during this test. High live loads are possible.
    Return to Standards List
    Return to new Environmental Test Equipment page

    »Telcordia (Bellcore) GR-326-CORE for fiber optics

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    4.4.2.1 Thermal Age Test 85°C for 168 hours

    FLX Series
    ET Series
    WP Series

    4.4.2.2 Thermal Cycle Test 168 hour cycle between -40 to 75°C

    FLX Series
    ET Series
    WP Series

    4.4.2.3 Humidity Aging Test 75°C/95% for 168 hours

    FLX Series
    EH Series
    WPH Series

    4.4.2.4 Humidity/Condensation Cycling Test -10 to 65°C w/condensation

    FLX Series
    EH Series
    WPH Series

    4.4.2.5 Dry-out Step 75°C for 24 hours

    FLX Series
    ET Series
    WP Series

    4.4.2.6 Post-condensation Thermal Cycle Test 168 hour cycle between -40 to 75°C

    FLX Series
    ET Series
    WP Series

    4.4.4.1 Dust Test Arizona Fine Dust

    D Series

    4.4.4.2 Adhesive Test 65°C for 7 days

    FLX Series
    ET Series
    WP Series

    Return to Standards List
    Return to new Environmental Test Equipment page

    »Telcordia (Bellcore) GR-468-CORE for optoelectronic devices

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    5.18 Accelerated Aging 70 or 85°C for 2000 to 5000 hours
    5.20 Temperature Cycling Temperature cycling from 70 or 85°C down to -40°C with ramp rates of 10°C/min
    5.21 Damp Heat 85°C and 85% R.H.
    5.23 Cyclic Moisture Resistance MIL-STD 883 Method 1004
    Return to Standards List
    Return to new Environmental Test Equipment page

    »Telcordia (Bellcore) GR-487-CORE for enclosures

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    3.26 R3-187 C. Simulation of High Ambient Temperature 46°C

    FLX Series
    ET Series
    WP Series

    3.27 R3-191 [155] Thermal Shock -40 to 60°C

    FLX Series
    ET Series
    WP Series

    3.34.2 R3-204 [166] Temperature Cycling/High Humidity 4 to 60°C w/R.H. **

    FLX Series
    EH Series
    WPH Series

    **requires repeated cycles of temperature between 4.4°C and 60°C, while controlling humidity at high levels:
    • 4.4 to 32°C increasing temperature, maintaining 90-95% humidity
    • 32 to 60°C with decreasing relative humidity (specific humidity of 0.24 kg of water/kg of dry air). This corresponds to 20% R.H. at 60°C.
    • 32 to 4.5°C decreasing temperature, maintaining humidity 80-95%

    Return to Standards List
    Return to new Environmental Test Equipment page

    »Telcordia (Bellcore) GR-1209-CORE for fiber optics

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    4.1.1 or 5.1.1 Temperature-Humidity Aging 85°C and 85% R.H. for 14 days
    4.1.2 or 5.1.2 Temperature-Humidity Cycling -40 to 75°C w/ 10% to 80% R.H. 14 day test

    FLX Series
    EH Series
    WPH Series

    4.1.3 or 5.1.3 Temperature Effects on DWDM Components -5 to 50°C w/uncontrolled humidity

    FLX Series
    ET Series
    WP Series

    Return to Standards List
    Return to new Environmental Test Equipment pag

    »Telcordia (Bellcore) GR-1221-CORE for fiber optics

    Paragraph
    Test Title
    Description
    Envirotronics Test Chamber
    6.2.3 Thermal Shock Liquid thermal shock 0 to -100°C

    TSL Series

    6.2.4 High Temperature Storage Test (dry heat) 85°C <40% R.H.

    FLX Series
    EH Series
    WPH Series

    6.2.5 High Temperature Storage Test (damp heat) 85°C and 85% R.H. up to 2000 hours

    EH Series

    6.2.6 Low Temperature -40°C for 2000 hours

    ET Series

    6.2.7 Temperature Cycling Test -40 to 70°C air thermal shock MIL-STD 883 Method 1010

    TS Series

    6.2.8 Cyclic Moisture Resistance Test 75°C, 85%-95% also 25°C and -40°C

    FLX Series
    EH Series
    WPH Series

    Return to Standards List